Three phase Rogowski coil converter FCA3000

from 422,30

FCA3000 is a three-channel current converter with DC outputs. It converts the values measured by a Rogowski coil into true RMS value.
FCA3000 can be used with any model or size of MFC150 Rogowski coils, according to the application. The coils can be connected directly to FCA3000 without any adapter, as FCA3000 integrates the input signal, shifting it by 90°. FCA3000 has three indipendent input channels, suitable for three transducers, and four DC outputs. The first three outputs correspond to each transducer, the forth gives the sum of the three current channels.
FCA3000 enclosure is a 9 module DIN rail for fast installation. FCA3000 can be used as current measurement interface with industrial devices such as PLC, SCADA systems, protection systems, control systems, metering equipments etc.



Catalogue
Datasheet
User manual

CONFIGURATIONS AVAILABLE IN THE E-COMMERCE REQUEST MORE INFORMATION

SKU: N/A Category: Tag:

NAMEDESCRIPTIONStockPRICEQUANTITYAdd to cart
Three phase Rogowski coil converter FCA3000 - FCA3000 2101.0010.0001FCA3000 three phase Rogowski coil converter full scale 3000A outputs 0...10VDCAvailability to be confirmed422,30€ VAT excluded Availability to be confirmed.
Contact us for more information
Three phase Rogowski coil converter FCA3000 - FCA3000 2101.0014.0001FCA3000 three phase Rogowski coil converter full scale 100000A outputs 0...10VDCAvailability to be confirmed443,20€ VAT excluded Availability to be confirmed.
Contact us for more information
Three phase Rogowski coil converter FCA3000 - FCA3000 2101.0020.0001FCA3000 three phase Rogowski coil converter 100mV/1kA@50Hz input sensitivity full scale 100000A outputs 0...10VDCAvailability to be confirmed443,20€ VAT excluded Availability to be confirmed.
Contact us for more information

Description

DO YOU NEED ADDITIONAL CONFIGURATIONS?

For other configurations contact the sales representative

TECHNICAL SPECIFICATIONS

Power supply
Rated voltage: 80…260 VAC (45…65 Hz)
Consumption: 3 VA max

Measuring inputs
Number: 3
Type: for Rogowski coil with signal equalization
Sensitivity: 100mV/1kA@50Hz (only if purchased without MFC150 coil)
Full scale: 3000 A
10000 A
other values on request (from 300 A to 300 kA)

Analog outputs
Number: 4
Type: 0…20 mA
4…20 mA
0…10 VDC
Response time: 150 ms (standard) – selectable by jumpers from 50 to 150 ms approx.
Typical accuracy: ± 1% reading ± 0.3% full scale

Environmental conditions
Operating temperature: from -10°C to +50°C
Storage temperature: from -25°C to +60°C
Relative humidity: 75% max without condensation

Case features
Material: plastic enclosure – noryl UL94-V0
Protection degree: IP51 (front panel); IP20 (terminals)
Terminals: conductors 2.5 mm2
Size / weight: 158x94x58 mm / 250 g approx

Standards compliance
Safety: 73/23/EEC and 93/68/EEC directives, EN61010.1 safety standard
EMC: 89/336/EEC directive and following modifications
93/31/EEC and 93/68/EEC, EN50081-2, EN50082-2, EN61326/A1